Journal of Oral and Maxillofacial Surgery
Volume 64, Issue 4 , Pages 642-651 , April 2006

Stability of Skeletal Class III Malocclusion After Combined Maxillary and Mandibular Procedures: Titanium Versus Resorbable Plates and Screws for Maxillary Fixation

  • Fabio Costa, MD

      Affiliations

    • Assistant Professor of Maxillo-Facial Surgery, Department of Maxillo-Facial Surgery, Faculty of Medicine, University of Udine, Udine, Italy
  • ,
  • Massimo Robiony, MD

      Affiliations

    • Associate Professor of Maxillo-Facial Surgery, Department of Maxillo-Facial Surgery, Faculty of Medicine, University of Udine, Udine, Italy
  • ,
  • Enrica Zorzan, MD

      Affiliations

    • Resident in Maxillo-Facial Surgery, Department of Maxillo-Facial Surgery, Faculty of Medicine, University of Udine, Udine, Italy
  • ,
  • Nicoletta Zerman, MD

      Affiliations

    • Associate Professor of Oral Pathology, Faculty of Medicine, University of Ferrara, Ferrara, Italy
  • ,
  • Massimo Politi, MD

      Affiliations

    • Professor of Maxillo-Facial Surgery and Head of Department of Maxillo-Facial Surgery, Faculty of Medicine, University of Udine, Udine, Italy
    • Corresponding Author InformationAddress correspondence and reprint requests to Dr Politi: Cattedra di Chirurgia Maxillo-Facciale, Policlinico Universitario, P.le S.Maria della Misericordia, 33100 Udine, Italy

References 

  1. Bailey LJ , Proffit WR , White RP . Trends in surgical treatment of Class III skeletal malrelationships . Int J Adult Orthodont Orthognath Surg . 1995;10:108
  2. Costa F , Robiony M , Politi M . Stability of Le Fort I osteotomy in maxillary advancement (review of the literature) . Int J Adult Orthodont Orthognath Surg . 1999;14:207
  3. Edwards RC , Kiely KD . Resorbable fixation of Le Fort I osteotomies . J Craniofac Surg . 1998;9:210
  4. Schmidt BL , Perrott DH , Mahan D , et al.   The removal of plates and screws after Le Fort I osteotomy . J Oral Maxillofac Surg . 1998;56:184
  5. Tharanon W , Sinn DP , Hobar PC , et al.   Surgical outcomes using bioabsorbable plating systems in paediatric craniofacial surgery . J Craniofac Surg . 1998;9:441
  6. Edwards RC , Kiely KD , Eppley BL . Fixation of bimaxillary osteotomies with resorbable plates and screws (Experience in 20 consecutive cases) . J Oral Maxillofac Surg . 2001;59:271
  7. Costa F , Robiony M , Sembronio S , et al.   Stability of skeletal Class III malocclusion after combined maxillary and mandibular procedures . Int J Adult Orthodont Orthognath Surg . 2001;16:179
  8. Tucker MR , White RP . Maxillary orthognathic surgery . In:  Tucker MR ,  Terry BC ,  White RP , et al. editor. Rigid Fixation for Maxillofacial Surgery . Philadelphia, PA: Lippincott; 1991;p. 221–250
  9. Houston WJB . The analysis of errors in orthodontic measurements . Am J Orthod . 1983;82:382
  10. Eppley BL , Sadove AM , Havlik RJ . Resorbable plate fixation in pediatric craniofacial surgery . Plast Reconstr Surg . 1997;100:1
  11. Edwards RC , Kiely KD , Eppley BL . Resorbable PLLA-PGA screw fixation of mandibular sagittal split osteotomies . J Craniofac Surg . 1999;10:230
  12. Edwards RC , Kiely KD , Eppley BL . Resorbable fixation techniques for genioplasty . J Oral Maxillofac Surg . 2000;58:269
  13. Haers PE , Suuronen R , Lindqvist C , et al.   Biodegradable polylactide plates and screws in orthognathic surgery (Technical note) . J Craniomaxillofac Surg . 1998;26:87
  14. Haers PE , Sailer HF . Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery (Short term skeletal stability and material related failures) . J Craniomaxillofac Surg . 1998;26:363
  15. Shand JM , Heggie A . Use of a resorbable fixation system in orthognathic surgery . Br J Oral Maxillofac Surg . 2000;38:335
  16. Norholt SE , Pedersen TK , Jensen J . Le Fort I miniplate osteosynthesis (A randomized, prospective study comparing resorbable PLLA/PGA with titanium) . Int J Oral Maxillofac Surg . 2004;33:245
  17. Araujo MM , Waite PD , Lemons JE . Strength analysis of Le Fort I osteotomy fixation (Titanium versus resorbable plates) . J Oral Maxillofac Surg . 2001;59:1034
  18. Politi M , Costa F , Cian R , et al.   Stability of skeletal class III malocclusion after combined maxillary and mandibular procedures (Rigid internal fixation versus wire osteosynthesis of the mandible) . J Oral Maxillofac Surg . 2004;62:169
  19. Turvey TA , Bell RB , Tejera TJ , et al.   The use of self-reinforced biodegradable bone plates and screws in orthognathic surgery . J Oral Maxillofac Surg . 2002;60:59
  20. Peltoniemi H , Ashammakhi N , Kontio R , et al.   The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery . Oral Surg Oral Med Oral Pathol Oral Radiol Endod . 2002;94:5

PII: S0278-2391(05)01849-5

doi: 10.1016/j.joms.2005.11.043

Journal of Oral and Maxillofacial Surgery
Volume 64, Issue 4 , Pages 642-651 , April 2006