« Previous
Next »
Journal of Oral and Maxillofacial Surgery
Volume 64, Issue 7
, Pages 1038-1048
, July 2006
A Comparative Study of 2 Implants Used to Repair Inferior Orbital Wall Bony Defects: Autogenous Bone Graft Versus Bioresorbable Poly-L/DL-Lactide [P(L/DL)LA 70/30] Plate
References
- . Orbital floor repair with antral wall bone grafts . Plast Reconstr Surg . 1966;37:62
-
.
Experience with various procedures in the treatment of orbital floor fractures
.
J Oral Maxillofac Surg
. 1981;9:81
- . Blow-out fracture of the orbit. Diagnostic and therapeutic considerations and results in 90 patients treated . J Maxillofac Surg . 1982;10:155
-
.
Medial orbital wall fracture with enophthalmos
.
J Craniomaxillofac Surg
. 1988;16:5
- . Autogene Knochentransplantate zur Versorgung der traumatisch geschädigten orbita . Ophthalmologe . 2001;98:178
- . Assessment of internal orbital reconstruction for pure blowout fractures (Cranial bone grafts versus titanium mesh) . J Oral Maxillofac Surg . 2003;61:442
-
Physical and monetary costs associated with autogenous bone graft harvesting
.
Am J Orthop
. 2003;32:18
- Bone-graft reconstruction of the monkey orbital floor with iliac grafts and titanium mesh plates (A histometric study) . Plast Reconstr Surg . 1993;91:769
- . Iliac crest bone graft harvest donor site morbidity. A statistical evaluation . Spine . 1995;20:1055
-
Comparison of anterior and posterior iliac crest bone grafts in terms of harvest-site morbidity and functional outcomes
.
J Bone Joint Surg Am
. 2002;84:716
-
.
The repair of fractures of the orbital floor using biodegradable polylactic acid
.
Oral Surg
. 1972;33:28
- Reconstruction of orbital floor with polydioxane plate . Int J Oral Maxillofac Surg . 1991;20:83
- Utilisation de la cupule en PDS dans les fractures orbito-malares . Rev Stomatol Chir Maxillofac . 1998;90:48
-
.
Resorbierbare PDS-folien zur orbitadefekt-uberbruckung im tierexperimentellen vergleich
.
Dtsc Z Mund Kiefer Gesichts Chir
. 1994;18:100
- . Self-reinforced polyglycolic acid membrane (A bioresorbable material for orbital floor repair) . Br J Oral Maxillofac Surg . 1995;33:220
- Poly(L-lactide) implants for repair of human orbital floor defects (Clinical and magnetic resonance imaging evaluation of long-term results) . J Oral Maxillofac Surg . 1996;54:9
- Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant . Int J Oral Maxillofac Surg . 2001;30:278
- Bioresorbable poly-L/DL-Lactide [P(L/DL)LA 70/30] plates are reliable for repairing of large inferior orbital wall bony defects (A pilot study) . J Oral Maxillofac Surg . 2006;64:47
-
.
Secondary correction of traumatic enophthalmos with auto- and alloplastic implants
.
Rev Stomatol Maxillofac
. 1993;194:37
-
.
A comparison of parietal and iliac crest bone grafts for orbital reconstruction
.
J Oral Maxillofacial Surg
. 2002;60:44
-
.
Traumatic enophthalmos
.
Arch Ophthalmol
. 1943;30:718
- Studies on enophthalmos: II. The measurement of orbital injuries and their treatment by quantitative computed tomography . Plast Reconstr Surg . 1986;77:203
-
.
The conservative approach. Management of blow out fractures of the orbital floor
.
Survey Ophthalmol
. 1991;35:292
- . A review of 128 patients with orbital fractures . Am J Ophthalmol . 1974;78:655
- Long-term results after primary restoration of the orbital floor . J Craniomaxillofac Surg . 1995;23:31
- . In vitro hydrolysis of self-reinforced polylactide composites . Med Biol Eng Comput . 1996;34:127
- . Processing and characterization of absorbable polylactide polymers for use in surgical implants . J Appl Biomater . 1994;5:133
- Orbital floor reconstruction with poly-L/D-lactide implants (Clinical, radiological and immunohistochemical study in sheep) . Int J Oral Maxillofac Surg . 2004;33:361
- Polylactic acid for surgical implants . Arch Surg . 1996;93:839
- . Preliminary report on the osteogenic potential of a biodegradable copolymer of polylactide (PLA) and polyglycolide (PGA) . J Biomed Mater Res . 1938;17:71
- Consolidation of craniotomy lines after resorbable polylactide and titanium plating (A comparative experimental study in sheep) . Plast Reconstr Surg . 1998;101:123
- Biodegradable semirigid plate and miniscrew fixation compared with rigid titanium fixation in experimental calvarial osteotomy . J Neurosurg . 1999;90:910
- SR-PLLA and SR-PGA miniscrews (Biodegradation and tissue reactions in the calvarium and dura mater) . J Craniomaxillofac Surg . 1999;27:42
-
.
Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
.
Clin Orthop
. 1992;278:193
-
Self-reinforced bioresorbable poly-L/DL-Lactide [SR-P(L/DL)LA] 70/30 miniplates and miniscrews are reliable for fixation of anterior mandibular fractures
(A pilot study)
.
Oral Surg Oral Med Oral Pathol
. 2004;97:312
- . Resorbable plate fixation in pediatric craniofacial surgery . Plast Reconstr Surg . 1997;100:1
- . Enophthalmos and diplopia in fractures of the orbital floor . Br J Plast Surg . 1975;9:265
-
Orbital “blow-in” fracture
(MRI)
.
Neuroradiol
. 1993;35:612
-
Proton spin tomography of the orbit in post-traumatic motility disorders
.
Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr
. 1995;163:127
- The free flap and plate in oromandibular reconstruction (Long-term review and indications) . Plast Reconstr Surg . 1995;95:1018
PII: S0278-2391(06)00378-8
doi: 10.1016/j.joms.2006.03.010
© 2006 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Oral and Maxillofacial Surgery
Volume 64, Issue 7
, Pages 1038-1048
, July 2006
