Journal of Oral and Maxillofacial Surgery
Volume 65, Issue 6 , Pages 1109-1116 , June 2007

Biomechanical Evaluation of Le Fort I Maxillary Fracture Plating Techniques

  • Hang Wang, DDS, MD, PhD

      Affiliations

    • Research Fellow, Key Laboratory of Biomedical Engineering, Department of Oral and Maxillofacial Surgery, West China Stomatology College, Sichuan University, Sichuan, China.
  • ,
  • Meng-Shi Chen, MSC

      Affiliations

    • Professor, Key Laboratory of Biomedical Engineering, West China Stomatology College, Sichuan University, Sichuan, China.
  • ,
  • Yu-Bo Fan, ScD

      Affiliations

    • Professor and Chairman, Key Laboratory of Biomedical Engineering, West China Stomatology College, Sichuan University, Sichuan, China.
  • ,
  • Wei Tang, DDS, PhD

      Affiliations

    • Associate Professor, Department of Oral and Maxillofacial Surgery, West China Stomatology College, Sichuan University, Sichuan, China.
  • ,
  • Wei-Dong Tian, DDS, PhD

      Affiliations

    • Professor and Chairman, Department of Oral and Maxillofacial Surgery, West China Stomatology College, Sichuan University, Sichuan, China.
    • Corresponding Author InformationAddress correspondence and reprint requests to Dr Tian: Department of Oral and Maxillofacial Surgery, West China Stomatology College, No. 14, 3rd Section, Renmin Road, Chengdu 610041, Sichuan University, P.R. China

References 

  1. Champy M, Lodde JP, Schmidtt R, et al. Mandibular osteosynthesis by miniature screwed plates via a buccal approach. J Maxillofac Surg. 1978;6:14
  2. Haug RH, Fattahi TT, Goltz M. A biomechanical evaluation of mandibular angle fracture plating techniques. J Oral Maxillofac Surg. 2001;59:1199
  3. Wagner A, Krach W, Schicho K, et al. A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002;94:678
  4. Prein J, Assael LA, Klotch DW, et al. Manual of Internal Fixation in the Cranio-Facial Skeleton (ed 2). Berlin, Heidelberg: Springer-Verlag; 1998;
  5. Mosbah MR, Oloyede D, Koppel DA, et al. Miniplate removal in trauma and orthognathic surgery—a retrospective study. Int J Oral Maxillofac Surg. 2003;32:148
  6. Alberts LR, Phillips KO, Tu HK, et al. A biologic model for assessment of osseous strain patterns and plating systems in the human maxilla. J Oral Maxillofac Surg. 2003;61:79
  7. Haug RH, Nuveen EJ, Barber JE, et al. An in vitro evaluation of distractors used for osteogenesis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998;86:648
  8. Haug RH, Barber EJ, Reifeis R. A comparison of mandibular angle fracture plating techniques. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1996;82:257
  9. Tanne K, Lu YC, Tanaka E, et al. Biomechanical changes of the mandible orthopaedic chin cup force studied in a three-dimensional finite element model. Eur J Orthod. 1993;15:527
  10. Tanne K, Tanaka E, Sakuda M. Stress distribution in the temporomandibular joint produced by orthopedic chincup forces applied in varying directions: A three-dimensional analytic approach with the finite element method. Am J Orthod Dentofacial Orthop. 1996;110:502
  11. Baron P, Debussy T. A biomechanical functional analysis of the masticatory muscles in man. Arch Oral Biol. 1979;24:547
  12. van Eijden TM, Raadsheer MC. Heterogeneity of fiber and sarcomere length in the human masseter muscle. Anat Rec. 1992;232:78
  13. van Eijden TM, Koolstra JH, Brugman P. Three-dimensional structure of the human temporalis muscle. Anat Rec. 1996;246:565
  14. van Eijden TM, Korfage JA, Brugman P. Architecture of the human jaw-closing and jaw-opening muscles. Anat Rec. 1997;248:464
  15. Korioth TW, Hannam AG. Mandibular forces during simulated tooth clenching. J Orofac Pain. 1994;8:178
  16. Throckmorton GS, Ellis E. The relationship between surgical changes in dentofacial morphology and changes in maximum bite force. J Oral Maxillofac Surg. 2001;59:620
  17. Ellis E, Throckmorton GS, Sinn DP. Bite forces before and after surgical correction of mandibular prognathism. J Oral Maxillofac Surg. 1996;54:176
  18. Harada K, Watanabe M, Ohkura K, et al. Measure of bite forces and occlusal contact area before and after bilateral sagittal split ramus osteotomy of the mandible using a new pressure-sensitive device: A preliminary report. J Oral Maxillofac Surg. 2000;58:370
  19. Sicher H, De Brul EL. Oral Anatomy. (ed 5).. St Louis: CV Mosby; 1970;
  20. Manson PN, Hoopes JE, Su CT. Structural pillars of the facial skeleton: An approach to the management of Le Fort fractures. Plast Reconstr Surg. 1980;66:54
  21. Gruss JS, Mackinnon SE. Complex maxillary fractures: Role of buttress reconstruction and immediate bone grafts. Plast Reconstr Surg. 1986;78:9
  22. Throckmorton GS, Buschang PH, Ellis E. Improvement of maximum occlusal forces after orthognathic surgery. J Oral Maxillofac Surg. 1996;54:1080
  23. Tate GS, Ellis E, Throckmorton G. Bite forces in patients treated for mandibular angle fractures: Implications for fixation recommendations. J Oral Maxillofac Surg. 1994;52:734
  24. Wang H, Chen MS, Tian WD, et al. Stress distribution of mandible under different loading and biting condition. Sichuan Da Xue Xue Bao Yi Xue Ban. 2004;35:516
  25. Soballe K. Hydroxyapatite ceramic coating for bone implant fixation: Mechanical and histological studies in dogs. Acta Orthop Scand Suppl. 1993;255:1
  26. Perren SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res. 1979;138:175
  27. Bergsma JE. Late complications using poly (lactide) osteosyntheses (Thesis). Groningen, The Netherlands: University of Groningen; 1995;

PII: S0278-2391(06)01930-6

doi: 10.1016/j.joms.2006.10.020

Journal of Oral and Maxillofacial Surgery
Volume 65, Issue 6 , Pages 1109-1116 , June 2007