Journal of Oral and Maxillofacial Surgery
Volume 65, Issue 11 , Pages 2169-2175 , November 2007

Histological and Histomorphometric Analysis of the Bone–Screw Interface in the Mandibular Body After Using a 2.0-mm Miniplate System: An Experimental Study in Dogs

  • Thiago Iafelice dos Santos, DDS

      Affiliations

    • Graduate Student, Department of Oral and Maxillofacial Surgery and Periodontology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • ,
  • Paulo Tambasco de Oliveira, DDS, PhD

      Affiliations

    • Assistant Professor, Division of Oral Histology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • ,
  • Adalberto Luiz Rosa, DDS, PhD

      Affiliations

    • Associate Professor, Department of Oral and Maxillofacial Surgery and Periodontology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • ,
  • Valdemar Mallet da Rocha Barros, DDS, PhD

      Affiliations

    • Professor, Department of Oral and Maxillofacial Surgery and Periodontology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • ,
  • Vula Papalexiou, DDS, PhD, MS

      Affiliations

    • Formerly, PhD Student, Department of Oral and Maxillofacial Surgery and Periodontology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil; Currently, Adjunct Professor, Ponticifal Catholic University of Parana, Parana, Curitiba, Brazil.
  • ,
  • Cássio Edvard Sverzut, DDS, PhD

      Affiliations

    • Associate Professor, Department of Oral and Maxillofacial Surgery and Periodontology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
    • Corresponding Author InformationAddress correspondence and reprint requests to Dr Sverzut: Department of Oral and Maxillofacial Surgery and Periodontology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Av do Cafe, s/n—Campus USP, 14040-904 Ribeirão Preto, SP, Brazil

References 

  1. Champy M, Lodde JP, Schmitt R, et al. Mandibular osteosynthesis by miniaturized screwed plate via a buccal approach. J Maxillofac Surg. 1978;6:14
  2. Ikemura K, Hidaka H, Etoh T, et al. Osteosynthesis in facial bone fractures using miniplates: Clinical and experimental studies. J Oral Maxillofac Surg. 1988;46:10
  3. Bähr W. Comparison of torque measurements between cortical screws and emergency replacement screws in the cadaver mandible. J Oral Maxillofac Surg. 1992;50:46
  4. Gabrielli MAC, Gabrielli MFR, Marcantonio E, et al. Fixation of mandibular fractures with 2.0 mm miniplates: Review of 191 cases. J Oral Maxillofac Surg. 2003;61:430
  5. Bähr W, Lessing R. The response of midfacial bone in sheep to loaded osteosynthesis screws in pretapped and nontapped implant sites. J Oral Maxillofac Surg. 1992;50:1289
  6. Cheung LK, Samman N, Pang M, et al. Titanium miniplate fixation for osteotomies in facial fibrous dysplasia: A histologic study of the screw/bone interface. Int J Oral Maxillofac Surg. 1995;24:401
  7. Hirai H, Okumura A, Goto M, et al. Histologic study of the bone adjacent to titanium bone screws used for mandibular fracture treatment. J Oral Maxillofac Surg. 2001;59:531
  8. Schön R, Schmelzeisen R, Shirota T, et al. Tissue reaction around miniplates used for the fixation of vascularized iliac crest bone grafts. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997;83:433
  9. Prein J. Manual of Internal Fixation in the Cranio-Facial Skeleton (. In: ed 2. Berlin: Springer-Verlag; 1998;p. 67
  10. Kim Y-K, Yeo H-H, Lim S-C. Tissue response to titanium plates: A transmitted electron microscopic study. J Oral Maxillofac Surg. 1997;55:322
  11. Langford R, Frame JW. Tissue changes adjacent to titanium plates in patients. J Craniomaxillofac Surg. 2002;30:103
  12. Clokie CM, Warshawsky H. Morphologic and radioautographic studies of bone formation in relation to titanium implants using the rat tibia as a model. Int J Oral Maxillofac Implants. 1995;10:155
  13. Allan W, Williams ED, Kerawala CJ. Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws. Br J Oral Maxillofac Surg. 2005;43:314
  14. Matthew IR, Frame JW, Browne RM, et al. In vivo surface analysis of titanium and stainless steel miniplates and screws. Int J Oral Maxillofac Surg. 1996;25:463
  15. Ray MS, Matthew IR, Frame JW. Metallic fragments on the surface of miniplates and screws before insertion. Br J Oral Maxillofac Surg. 1998;37:14

 This work was supported by The State of São Paulo Research Foundation (FAPESP grant 02/06855-3 for C.E.S.).

PII: S0278-2391(06)02110-0

doi: 10.1016/j.joms.2006.11.020

Journal of Oral and Maxillofacial Surgery
Volume 65, Issue 11 , Pages 2169-2175 , November 2007