Journal of Oral and Maxillofacial Surgery
Volume 66, Issue 5 , Pages 900-904 , May 2008

Skeletal Stability After Mandibular Setback Surgery: Bicortical Fixation Using a 2.0-mm Locking Plate System Versus Monocortical Fixation Using a Nonlocking Plate System

  • Koichiro Ueki, DDS, PhD

      Affiliations

    • Clinical Fellow, Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kanazawa University, Kanazawa, Japan.
    • Corresponding Author InformationAddress correspondence and reprint requests to Dr Ueki: Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kanazawa University, 13-1 Takaramachi, Kanazawa 920-8641, Japan
  • ,
  • Yukari Hashiba, DDS

      Affiliations

    • Graduate Student, Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kanazawa University, Kanazawa, Japan.
  • ,
  • Kohei Marukawa, DDS, PhD

      Affiliations

    • Clinical Fellow, Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kanazawa University, Kanazawa, Japan.
  • ,
  • Shamiul Alam, BDS, PhD

      Affiliations

    • Postdoctoral Fellow, Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kanazawa University, Kanazawa, Japan.
  • ,
  • Kiyomasa Nakagawa, DDS, PhD

      Affiliations

    • Associate Professor, Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kanazawa University, Kanazawa, Japan.
  • ,
  • Etsuhide Yamamoto, DDS, PhD

      Affiliations

    • Chief Professor, Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kanazawa University, Kanazawa, Japan.

References 

  1. Tucker MR. Orthognathic surgery versus orthodontic camouflage in the treatment of mandibular deficiency. J Oral Maxillofac Surg. 1995;53:572
  2. Scheerlinck JPO, Stoelinga PJW, Blijdorp PA, et al. Sagittal split advancement osteotomies stabilitized with miniplates: A 2-to 5-year follow-up. Int J Oral Maxillofac Surg. 1994;23:127
  3. Tulasne JF, Schendel SA. Transoral placement of rigid fixation following sagittal ramus split osteotomy. J Oral Maxillofac Surg. 1989;47:651
  4. Blomqvist JE, Isaksson S. Skeletal stability after mandibular advancement: A comparison of two rigid internal fixation techniques. J Oral Maxillofac Surg. 1994;52:1133
  5. Choi BH, Min YS, Yi CK, et al. A comparison of the stability of miniplate with bicortical screw fixation after sagittal split setback. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000;90:416
  6. Haug RH, Street CC, Goltz M. Does plate adaptation affect stability? (A biomechanical comparison of locking and nonlocking plates). J Oral Maxillofac Surg. 2002;60:1321
  7. Ellis E, Graham J. Use of a 2.0-mm locking plate/screw system for mandibular fracture surgery. J Oral Maxillofac Surg. 2002;60:642
  8. Lazow SK, Berger JR. Transoral 2.0-mm locking miniplate fixation of mandibular fractures plus 1 week of maxillomandibular fixation: A prospective study. J Oral Maxillofac Surg. 2005;63:1737
  9. Chiodo TA, Ziccardi VB, Janal M, et al. Failure strength of 2.0 locking versus 2.0 conventional synthesis mandibular plates: A laboratory model. J Oral Maxillofac Surg. 2006;64:1475
  10. Ueki K, Nakagawa K, Takatsuka S, et al. Plate fixation after mandibular osteotomy. Int J Oral Maxillofac Surg. 2001;30:490
  11. Hammer B, Ettlin D, Rahn B, et al. Stabilization of the short sagittal split osteotomy: In vitro testing of different plate and screw configurations. J Craniomaxillofac Surg. 1995;23:321
  12. Righi E, Carta M, Bruzzone AA, et al. Experimental analysis of internal rigid fixation osteosynthesis performed with titanium bone screw and plate systems. J Craniomaxillofac Surg. 1996;24:53
  13. Fujioka M, Hirano A, Fujii T. Complete breakage of miniplates: Two unusual complication cases after sagittal split osteotomies. J Jpn Craniomaxillofac Surg. 1998;14:79
  14. Chuong CJ, Borotikar B, Schwartz-Dabney C, et al. Mechanical characteristics of the mandible after bilateral sagittal split ramus osteotomy: Comparing 2 different fixation techniques. J Oral Maxillofac Surg. 2005;63:68
  15. Gutwald R, Alpert B, Schmelzeisen R. Principle and stability of locking plate. Keio J Med. 2003;52:21
  16. Herford AS, Ellis E. Use of a locking reconstruction bone plate/screw system for mandibular surgery. J Oral Maxillofac Surg. 1998;56:1261
  17. Klotch DW, Gal TJ, Gal RL. Assessment of plate use for mandibular reconstruction: Has changing technology made a difference?. Otolaryngol Head Neck Surg. 1999;121:388
  18. Lindquist C, Soderholm AL, Salo A, et al. A comparative study on four screw-plate locking systems in sheep: A clinical and radiological study. Int J Oral Maxillofac Surg. 2001;30:160
  19. Kirkpatrick D, Gandhi R, Van Sickels JE. Infection associated with locking reconstruction plates: A retrospective review. J Oral Maxillofac Surg. 2003;61:462
  20. Soderholm AL, Rahn BA, Skutnabb K, et al. Fixation with reconstruction plates under critical conditions: The role of screw characteristics. Int J Oral Maxillofac Surg. 1996;25:469
  21. Sikes JW, Smith BR, Mukherjee DP, et al. Comparison of fixation strengths of locking head and conventional screws, in fracture and reconstruction models. J Oral Maxillofac Surg. 1998;56:468
  22. Soderholm AL, Lindquist C, Skuntnabb K, et al. Bridging of mandibular defects with two different reconstruction systems: An experimental study. J Oral Maxillofac Surg. 1991;49:1098
  23. Engroff SL, Blanchaert RH, Von Fraunhofer JA. Mandibulotomy fixation: A laboratory analysis. J Oral Maxillofac Surg. 2003;61:1297
  24. Alder ME, Deahl T, Matteson SR, et al. Short-term change of condylar position after sagittal split osteotomy for mandibular advancement. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1999;87:159
  25. Kawamata A, Fujishita M, Nagahara K, et al. Three-dimensional computed tomography evaluation of postsurgical condylar displacement after mandibular osteotomy. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998;85:371
  26. Nishimura A, Sakurada S, Iwase M, et al. Position change in the mandibular condyle and amount of mouth opening after sagittal split ramus osteotomy with rigid or nonrigid osteosynthesis. J Oral Maxillofac Surg. 1997;55:672
  27. Oichs MW, LaBanc JP, Dolwick MF. The diagnosis and management of concomitant dentofacial deformity and temporomandibular disorder. Oral Maxillofac Surg Clin North Am. 1990;2:669
  28. Schultes G, Gagol A, Kärcher H. Change in the dimensions of milled mandibular model after mandibular sagittal split osteotomies. Br J Oral Maxillofac Surg. 1998;36:196
  29. Stroster TG, Pangrazio-Kulbersh V. Assessment of condylar position following bilateral sagittal split ramus osteotomy with wire fixation or rigid fixation. Int J Adult Orthod Orthogn Surg. 1994;9:55

PII: S0278-2391(07)01890-3

doi: 10.1016/j.joms.2007.08.033

Journal of Oral and Maxillofacial Surgery
Volume 66, Issue 5 , Pages 900-904 , May 2008