Journal of Oral and Maxillofacial Surgery
Volume 67, Issue 8 , Pages 1595-1599, August 2009

Factors Associated With the Stability of Mini-Implants for Orthodontic Anchorage: A Study of 414 Samples in Taiwan

  • Tzu-Ying Wu, DDS

      Affiliations

    • Attending Physician, Section of Orthodontics and Pediatric Dentistry, Department of Stomatology, Taipei Veterans General Hospital, and School of Dentistry, National Yang-Ming University, Taipei, Taiwan
  • ,
  • Shou-Hsin Kuang, DDS, DMSc

      Affiliations

    • Division Chief, Section of Orthodontics and Pediatric Dentistry, Department of Stomatology, Taipei Veterans General Hospital, and School of Dentistry, National Yang-Ming University, Taipei, Taiwan
  • ,
  • Cheng-Hsien Wu, DDS

      Affiliations

    • Attending Physician, Section of Oral and Maxillofacial Surgery, Department of Stomatology, Taipei Veterans General Hospital, and School of Dentistry, National Yang-Ming University, Taipei, Taiwan
    • Corresponding Author InformationAddress correspondence and reprint requests to Dr Wu: Section of Oral and Maxillofacial Surgery, Department of Stomatology, Taipei Veterans General Hospital, and School of Dentistry, National Yang-Ming University, No. 201, Sec. 2, Shipai Road, Beitou District, Taipei City, 112 17, Taiwan

Purpose

To evaluate failure rates and factors associated with the stability of mini-implants used for orthodontic anchorage.

Patients and Methods

We enrolled 166 patients (35 male patients and 131 female patients) who had consecutively received mini-implants for orthodontic anchorage at the Section of Orthodontics and Pediatric Dentistry, Taipei Veterans General Hospital (Taipei, Taiwan) from January 2001 to December 2006. A total of 414 mini-implants with diameters ranging from 1.2 to 2.0 mm were evaluated. Clinical variables for analysis were divided into host-related and implant-related factors. Mini-implants that could be maintained for orthodontic anchorage for more than 6 months were considered to be successful. Statistical analysis was used to evaluate the failure rate in our study cohort and to identify possible associated factors.

Results

The overall failure rate was 10.1% (42 of 414 screws) with orthodontic force loading for more than 6 months. Most failures were due to loosening and occurred within the first 2 weeks. Differences in overall failure rates for the maxilla and mandible (9.3% and 16.3%, respectively) were not statistically significant. A lower failure rate was found for the maxilla with implant diameters equal to or less than 1.4 mm (P = .036). The left side had a lower failure rate than the right (6.7% vs 13.9%, P = .019). Length and type of mini-implants, age, and gender were not associated with mini-implant failure.

Conclusions

Use of mini-implants for anchorage is reliable. In our study the overall success rate was 89.9%. Careful diameter selection for different locations is essential. In the maxilla an implant diameter equal to or less than 1.4 mm is recommended. In the mandible an implant diameter larger than 1.4 mm is suggested for better orthodontic anchorage. Hygienic care of implantation sites should also be emphasized for long-term success of mini-implant anchorage.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0278-2391(09)00515-1

doi:10.1016/j.joms.2009.04.015

Journal of Oral and Maxillofacial Surgery
Volume 67, Issue 8 , Pages 1595-1599, August 2009