Journal of Oral and Maxillofacial Surgery
Volume 70, Issue 2 , Pages 378-383 , February 2012

Can an Arch Bar Replace a Second Lag Screw in Management of Anterior Mandibular Fractures?

  • Hany A. Emam, BDS, MS

      Affiliations

    • Resident, Department of Oral and Maxillofacial Surgery, Georgia's Health Sciences University Medical College of Georgia, Augusta, GA; and Assistant Lecturer, Department of Oral and Maxillofacial Surgery, Cairo University, Cairo, Egypt
  • ,
  • Mark R. Stevens, DDS

      Affiliations

    • Chairman, Department of Oral and Maxillofacial Surgery, Georgia's Health Sciences University/Medical, College of Georgia, Augusta, GA
    • Corresponding Author InformationAddress correspondence and reprint requests to Dr Stevens: Department of Oral and Maxillofacial Surgery, Medical College of Georgia, Georgia's Health Sciences University, 1120 15th Street, Augusta, GA 30912

References 

  1. Chu L , Gussack GS , Muller T . A treatment protocol for mandible fractures . J Trauma . 1994;36:48
  2. Ilg P , Ellis E . A comparison of two methods for inserting lag screws . J Oral Maxillofac Surg . 1992;50:119
  3. Fonseca RJ , Marciani RD , Hendler BH . In: (ed 1). Oral and Maxillofacial Surgery . vol 3:Philadelphia: WB Saunders; 2001;p. 117–120
  4. Ellis E , Ghali GE . Lag screw fixation of anterior mandibular fractures . J Oral Maxillofac Surg . 1991;49:13
  5. Madsen MJ , McDaniel CA , Haug RH . A biomechanical evaluation of plating techniques used for reconstructing mandibular symphysis/parasymphysis fractures . J Oral Maxillofac Surg . 2008;66:2012
  6. Terheyden H , Mühlendyck C , Sprengel M , et al.  Self-adapting washer system for lag screw fixation of mandibular fractures (part II: In vitro mechanical characterization of 2.3 and 2.7 mm lag screw prototypes and in vivo removal torque after healing) . J Craniomaxillofac Surg . 1999;27:243
  7. Kallela I , Ilzuka T , Laine P , et al.  Lag-screw fixation of mandibular parasymphyseal and angle fractures . Oral Surg Oral Med Oral Pathol Oral Radiol Endod . 1996;82:510
  8. Zachariades N , Mezitis M , Papademetriou I . Use of lag screws for the management of mandibular trauma . Oral Surg Oral Med Oral Pathol Oral Radiol Endod . 1996;81:164
  9. Kuriakose MA , Fardy M , Sirikumara M , et al.  A comparative review of 266 mandibular fractures with internal fixation using rigid (AO/ASIF) plates or mini-plates . Br J Oral Maxillofac Surg . 1996;34:315
  10. Tuovinen V , Norholt SE , Sindet-Pedersen S , et al.  A retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium miniplates . J Oral Maxillofac Surg . 1994;52:931
  11. Niederdellmann H , Akuamoa-Boateng E , Uhlig G . Lag-screw osteosynthesis: A new procedure for treating fractures of the mandibular angle . J Oral Surg . 1981;39:938
  12. Ellis E , Ghali GE . Lag screw fixation of mandibular angle fractures . J Oral Maxillofac Surg . 1991;49:234